Scientific and Technical Publications
Standalone 3Dresyns research, reviews and technical publications on materials, measurement, processing and applications. Browse the most recent work first, with source descriptions, available full texts and DOI links.
Latest publications
- Radiopacity and Bending Performance in Photopolymer Bone-Plate Concepts
View description
X-ray attenuation through a specimen and bending performance can share a thickness dependence without being interchangeable measures of implant visibility. This analytical study examines that coupling for homogeneous rectangular photopolymer sections with distributed radiopacity. No new experimental observations or unpublished collaborative results are used. For a narrow monoenergetic beam normal to a plate face in air, normalized attenuation depth is t = ar, flexural rigidity is β = er³, and stress-limited bending moment is q = sr². Here r is relative thickness and a, e and s are relative attenuation, modulus and stress-threshold parameters. At equal attenuation depth in air, the latter ratios are e/a³ and s/a². A separate derivation addresses excess attenuation over a displaced homogeneous background; the same algebra applies only after replacing a by a positive background-contrast ratio. Four hypothetical air-transmission scenarios demonstrate ranking reversals and incompatible requirements. A closed-form thickness interval combines attenuation, rigidity, moment and geometric bounds; bounded uncertainty can remove a nominally admissible interval. Projection direction and marker-based localization limit the scope of the coupling. The contribution integrates established relations into an auditable screening calculation, not a validated implant-design method. Clinical image quality, manufacturing, fatigue and biological qualification remain separate experimental questions.
Keywords: radiopacity; masked stereolithography; photopolymer composite; bone plate; flexural rigidity; thickness; bounded uncertainty.
- Shorter Laser Wavelength Does Not Guarantee Better Sintering: An Evidence Framework for Transferring Polyethylene Powders between 976 nm, 1064 nm and 10.6 µm Laser Systems
View description
Methodological review of polyethylene powder-bed sintering across nominal laser wavelengths of 976 nm, 1064 nm and 10.6 µm. It distinguishes photon energy from absorbed process energy and proposes a three-gate framework for optical coupling, thermal and process feasibility, and final-part acceptance, with PASS, FAIL and INDETERMINATE outcomes. Synthetic screening cases illustrate why wavelength alone cannot rank absorbed energy or part performance. The article does not report new polyethylene measurements or validate commercial machines, grades or universal settings.
- From Micromold Accuracy to Drug Delivery: Why Geometric Fidelity Does Not Establish Transdermal Performance
View description
Dimensional conformity and run-to-run reproducibility are distinct manufacturing attributes: a process can consistently reproduce a geometry that deviates from its design. Neither attribute alone establishes skin insertion, drug release, tissue deposition, receptor permeation, delivered dose, or clinical exposure. We examine the claim boundaries of these measurements using the experimental sequence reported by Antonara et al. (2025), who employed an LCD-printed 3Dresyn Bioflex D60 MB resin mold to cast ropinirole-loaded poly(vinyl alcohol) microneedles. Their results include geometry-specific dimensional measurements, Parafilm insertion screening and ex vivo permeation through porcine skin. We organize a stage-resolved evidence map, adapt established compartmental mass accounting to this manufacturing route, and use bounded conditional fractions to examine what can and cannot be inferred across fabrication, insertion and transport. Four completely hypothetical parameter sets demonstrate non-identifiability: equal geometric fidelity and initial loading can accompany different receptor amounts, while the same receptor amount may arise from distinct upstream losses. A prospective qualification design separates mold accuracy, demolding, application mechanics, drug recovery, tissue retention and receptor permeation. The contribution is an auditable reporting framework, not a new mass-balance principle, an empirical reanalysis or a validated clinical dose model. Supplier materials, printed tools and final drug-delivery systems must be evaluated in their respective roles, including possible process-derived transfer from mold to product.
- Degradation Is Not Disappearance: Mass Loss, Mechanical Integrity and Functional Lifetime of Degradable 3D-Printed Photopolymers
View description
Chemical transformation, specimen mass retention, mechanical properties and usable functional lifetime are distinct quantities. A printed structure may fail a defined function while retaining nearly all its dry mass, or exhibit erosion before losing the specified load capacity. An increased modulus may also coexist with declining ductility. This methodological paper specifies the tested article, mandatory application endpoints, predeclared acceptance regions and separate chemical and functional observations. It distinguishes the true first exit from an acceptance region from the first failure detected on a sampling schedule. The latter does not generally determine the former without assumptions on recovery and observation. Destructive endpoints require matched cross-sectional cohorts rather than repeated measurements on the same specimen; marginal endpoint results alone do not establish joint specimen acceptance. Two reproducible exponential counterexamples and a nonmonotone stiffness example illustrate opposite possible event orderings without modeling any commercial formulation. The contribution is a claim-specific reporting and adjudication procedure, including explicit censoring and uncertainty, rather than discovery of degradation-mechanics decoupling. Existing hydrolytic-degradation standards already address complementary measurements. A prospective validation design is proposed; no new measurements, enzyme-specific kinetic laws, medical safety claims or empirical predictive performance are asserted.
- Cell Viability Does Not Establish Functional Biocompatibility: Limits of biological testing in 3D-printed photopolymers and a claim-specific evidence concordance framework
View description
Cell viability is an endpoint-specific observation, not proof of functional biocompatibility or medical-device safety. This critical analysis examines Liao et al. (2025), who studied C2C12 responses and mechanical performance in printed resins; Jönsson et al. (2025), who evaluated wet-autoclave processing, extractables, adipose-derived stem cells and molecular and differentiation endpoints; and Licata et al. (2024), who documented different responses between human induced pluripotent stem cells and fibroblasts. Two studies were selected because they included products of the author's company; Licata was added to examine transfer across cell types. The Liao preprint reports an unfavourable C2C12 response for 3Dresyns Bioflex A10 MB in its tested configurations. That finding must be retained, but it does not alone identify the causal contribution of the supplied formulation, measured optical process, conversion or residual extractables. The Liao protocol included a manufacturer-recommended UNW2 wash followed by heated water and a post-curing intensity reported by the curing-station manufacturer (Phrozen), not measured at the specimens. These details constrain explanations based solely on omitted aqueous washing or assumed low post-cure intensity, without establishing causation. Jönsson observed selected transcriptomic changes despite favourable gross-cell outcomes; differentiation results and their limits are separately considered. We refine a claim-specific evidence concordance (CEC) record distinguishing contextual relevance, reliability, observed direction and experimentally supported evidence transfer. An additional process-control analysis explains the limits of generic supplier instructions and nominal light-source specifications for establishing actual optical exposure, conversion and extractables, and separates the responsibilities of resin supplier, fabricator, testing laboratory and legal device manufacturer. No new biological experiments, clinical inferences, material ranking or validation of CEC are claimed.
- Devices printed in 3Dresyns photopolymers for ESRF crystallography and spectroscopy
View description
Dimensional fidelity and its consequences for flow exposure and optical alignment
Printed photopolymers can influence a scientific measurement through the geometry and stability of the device surrounding the sample. This analytical technical note examines two published applications at the European Synchrotron Radiation Facility involving 3Dresyn MF RTP1 and 3Dresyn UHF, then develops an analytical framework for translating dimensional deviations into changes in sample exposure. For a rigid channel whose width and height are scaled by a common factor s at unchanged length, the nominal transit time scales as s² at fixed volumetric flow. At fixed total pressure, it instead scales as (1 − f)s² + fs⁻², where f is the fraction of the original circuit resistance contributed by the changing channel. Under the model assumptions, a 5% enlargement increases transit time by 10.25% at fixed flow, the control mode reported for 3D-MiXD. A hypothetical circuit operated at fixed pressure across the channel instead gives a 9.30% decrease. A rectangular duct calculation extends the analysis to unequal dimensional changes. A separate Gaussian illumination model relates positioning error in a stationary holder to local excitation fluence. These calculations provide conditional tolerance criteria and an experimental validation plan. They do not constitute measurements of either resin, a reconstruction of the complete published instruments, or a prediction of absolute radiation dose. The contribution is an explicit connection between manufacturing fidelity, operating conditions and measurement error that can be tested in subsequent experiments.
The accompanying reproducibility supplement provides the analytical code,
deterministic outputs, figures, manuscript sources and reference register. - 3D-printed crowns and bridges with 3Dresyn OD C&B MF and 3Dresyn OD C&B Ceramic: Composition and geometry in the comparison of stiffness and chemical release
View description
Direct printing of crowns and bridges enables the fabrication of restorations from photocurable formulations with different compositions. Material selection requires relating these differences to curing, design and the behaviour of the finished restoration. This work compares the commercial documentation for 3Dresyn OD C&B MF and 3Dresyn OD C&B Ceramic through a focused review of primary studies and a reproducible analysis of mass and stiffness. The first formulation is declared monomer-free; the second contains ceramic filler and, according to manufacturer information supplied by the author, is not a monomer-free formulation and has a higher density. The published density range requires verification of its compatibility with the stated filler loading and specification of the variant and liquid measurement conditions. The stated strength limits likewise do not establish an experimental ranking of the products. Geometry and stiffness are compared alongside chemical normalisation per restoration, surface area and organic mass, distinguishing exhaustive extraction from short-time diffusion. An idealised example shows that incorporating 25% filler by mass does not reduce the amount of organic phase in an equal-volume part by 25%. The literature demonstrates that design, processing and ageing modify outcomes, and provides clinical evidence that remains dependent on the product and follow-up period. A validation programme is proposed that connects composition, manufacturing, fatigue and chemical release. The contribution is a method for comparing two commercial materials without confusing their declared properties with the durability of a crown or bridge. No comparative experimental campaign on these products is presented.
Version 1. English and Spanish editions of the same work, deposited together.
- 3Dresyn OD BCI1 MF Bio in dental implantology: Commercial photopolymer material and validation of the finished implant
View description
3Dresyn OD BCI1 MF Bio is a commercial photopolymer resin for implant-related dental applications. It is supplied as a liquid for SLA, DLP and LCD. Its formulation is declared to be monomer-free, and the technical datasheet attributes a Young's modulus close to 3 GPa and strengths of up to 140 MPa to the processed solid. This article examines this existing product alongside metallic, ceramic and polymeric alternatives, distinguishing material specifications from validation of a finished implant. A reproducible analysis combines load sharing in series and in parallel with flexural rigidity: lower stiffness may increase the bone's share of the load, but may also increase deformation and compromise stability. The manufacturer's recommended diameters, differences between commercial documents and the scope of regulatory criteria are made explicit. The European framework includes the 2026 amendments concerning technical documentation and clinical investigations. Joint assessment of stability, fatigue in wet conditions and chemical release during ageing is proposed. The material's commercial availability is an industrial reality; the clinical benefit of a particular geometry requires evidence concerning the device and its manufacturing process.
Version 1. English and Spanish editions of the same work, deposited together.
- Directly printed aligners: process safety and manufacturer responsibility
View description
Joint assessment of chemical conversion, substance release and orthodontic response
Direct aligner printing produces the appliance geometry without thermoforming a sheet over a dental model. This design freedom creates a close dependence between formulation, printing, cleaning, post-curing and finished-device properties. This paper presents a targeted review of primary studies, publicly available material documentation and regulatory sources from the United States, European Union and Spain, consulted up to 8 November 2026. Reactive-group conversion, residual content, extractables, release during use and biological response are distinguished. The evidence examined shows that published properties cannot be transferred between formulations, procedures or geometries without justification. A proposed bench protocol identifies manufacturing conditions capable of meeting chemical, biological, geometric, optical and mechanical requirements simultaneously, including wet ageing and insertion-removal cycles. Its contribution is to connect these conditions with process tolerances, routine controls and documented responsibilities in point-of-care manufacturing. No new experimental campaign, commercial superiority ranking or demonstration of clinical safety is presented. Material conformity can support the aligner assessment within its scope, but must be related to the process actually performed and to the obligations of the relevant manufacturer.
The Spanish and English editions are two language versions of the same work, both Version 1.
- Thickness and function in photopolymer selection: 3Dresyn PEEK-like and 3Dresyn Nylon-like as application cases
View description
Spanish and English editions of the same work, Version 1, with shared scientific
supplementary material. Author: Juan Segurola, 3Dresyns.
Selecting a 3D printing resin requires relating its properties to part geometry and function. A section that carries a high force may tolerate little displacement before damage, while another may bend substantially under a lower force. This study uses 3Dresyn PEEK-like and 3Dresyn Nylon-like to explain this complementarity through technical documentation, the author’s qualitative observations and reproducible bending analysis. A thickness interval is formulated to meet service stiffness, stress limits, assembly displacement and maximum assembly force simultaneously. Two mathematical examples show that a stiffer material can enable a thinner section under load while having no admissible thickness when a larger bending displacement is required. Dimensional tolerances further narrow the interval. The examples do not represent product measurements. An experimental check is proposed to separate geometric contributions from possible changes in material state. The contribution is the application of established design criteria to photopolymer selection with incomplete commercial data; no universal toughness ranking is established and no new experimental campaign is reported.
Supplementary material
figures. The analytical examples are not experimental product measurements.
- Binder and thickness in choosing between direct printing and printed moulds for ceramics and metals
View description
English and Spanish editions of the same article, both Version 1. The English text is a complete translation of the Spanish edition. Both PDF editions are deposited together under this record. Contact: info@3Dresyns.com. © 2026. All rights reserved.
Powder-based ceramic and metal parts can be manufactured by direct photopolymerisation printing or by moulding in printed tools. The former uses powder dispersed in a photocurable resin; the latter uses a moulding feedstock with a conventional non-photoreactive binder, usually thermoplastic. The mould resin and the feedstock binder are different materials. Both routes subsequently require binder removal and sintering. This study examines when a binder that is easier to extract can compensate for the additional operations of making, filling and removing a mould. A targeted review of primary studies is combined with reproducible material and time balances. The comparison starts with the organic mass remaining with the powder after preliminary extraction. An example with powder loadings of 45% and 60% by volume shows how much each formulation must lose through extraction to reach thermal treatment with the same amount of organic matter. A simplified model relates this amount to gas generation and escape, permeability and thickness. The time balance includes extraction, drying and the dependence of printing time on height. The results explain why a smaller initial binder content does not guarantee a faster process and when the additional mould operations can be advantageous. A protocol is proposed to test these conditions using parts that meet the same final specification. The calculations are illustrative scenarios; no new experimental campaign or validation of commercial materials is presented.
- Commercial Feedstocks for MIM and CIM in Photopolymer Molds: Powder loading, binder removal, process compatibility and cost per accepted part
View description
The study brings together 19 grouped commercial entries from 11 suppliers, 19 records on loading or removal, and 51 references. It distinguishes ready-to-mold pellets, binders for compounding, suspensions and direct printing routes. The industrial focus is on reusable and sacrificial molds produced by SLA, DLP or LCD, including economical platforms when their process has been qualified. The analysis uses 40.00 EUR/kg for EB1 and 40.00 EUR/kg for IM-HDT-WS as project sponsor assumptions, not market quotations. It includes mass-volume conversions, a stage-based cost model and reproduced generic bronze scenarios. It provides no new experiments and does not demonstrate mechanical equivalence, supply availability or savings for a specific commercial combination.
English and Spanish editions of the same work, 31 pages each.
- Photopolymerised sacrificial moulds for the indirect manufacture of ceramics and metals: Joint design of injection stability and aqueous removal with partial binder extraction
View description
Indirect manufacturing with printed moulds allows the geometric freedom of photopolymerisation to be combined with the feedstocks used in ceramic and metal powder injection moulding. Its potential increases when the mould can be removed in water and the feedstock binder contains a fraction that is also extractable in that medium. The two operations can share a stage, although mould removal simultaneously changes water access and mechanical support for the part. This article analyses that interaction and proposes a design criterion connecting printed mould quality, stability during injection, the evolution of the part in the bath and quality after sintering. Published experimental evidence, manufacturer documentation and analytical deductions are distinguished. The article develops a mechanical approximation to explain the sensitivity of slender internal walls, a balance that separates mould removal from binder extraction, and a comparative protocol organised by process stage. The potential advantage of the indirect route lies in selecting separately the material that defines the geometry and the system that holds the powder together. Its usefulness must be demonstrated through geometry, integrity, time and cost per accepted part. This work is an analysis and methodological proposal; it reports no new experimental results and does not establish general superiority over direct printing.
English and Spanish editions of the same work
- Reporting Mechanical Properties of 3D Printing Resins
View description
Manufacturing Configuration, Cure State and Temporal Stability
The mechanical properties reported for a photopolymer resin correspond to specimens produced through a specific process. Changes in orientation, exposure, cleaning, post-curing or conditioning can alter the result without changing the commercial name of the material. This work examines how to retain that dependence when reporting typical values, ranges and specification limits. Established principles of documentation and comparability are applied to link each property to an identifiable material state and its test method, retaining the properties of that state together. A documentary example shows that combining maxima from two states can lead to a selection without joint support. A second example, based on coatings, illustrates why test age also forms part of the reported information. Mechanical evolution is distinguished from chemical conversion, avoiding attribution of every subsequent change to dark reaction. The proposal combines reference values, documented variation, acceptance requirements and evidence of compliance. The examples demonstrate the logical problem and its application, but do not quantify its commercial frequency or validate production performance.
- What a Curing Curve Can Identify
View description
Interpreting resin response without confounding it with test effects
A curing working curve, referred to here as CRT, relates radiant exposure to the resulting thickness of cured resin. Its usefulness depends on whether the light assigned to each sample and the measured thickness represent what occurred during the test. An excessively thin resin layer, an irradiance reading taken at a different position, or excessive micrometer tightening can alter the curve and, with it, the parameters used to interpret the material.
This study reanalyses 36 existing observations grouped into 12 exposure conditions. It aims to explain which conclusions the data support and which depend on the chosen model or on measurement assumptions. Two different optical models describe the nine conditions with measurable curing in very similar ways. A calculated curve lying close to the data is therefore insufficient to identify the physical mechanism that produced them.
The smallest maximum discrepancy from a Jacobs straight line is 7.938 µm. Curvature has a positive sign in all three blocks, whereas a fixed liquid-height cap applied to Jacobs gives a non-positive sign: that cap alone cannot explain the observed shape. The error scenarios delimit compatibility without measuring deformation or correcting the data.
A frame retained a nominal resin height of 2 mm for all 36 samples. This preparation provides a substantial margin above the largest recorded cured thickness of 162 µm. It does not, by itself, demonstrate the absence of oxygen inhibition. Applying a CRT to printing requires joint consideration of liquid height, oxygen access, exposure position, source spectrum and measurement procedure.
- Light Intensity versus Energy Dose in Vat Photopolymerization: Experimental Effects on Cure Depth and Adhesion
View description
Experimental study of a fixed transparent PEEK-like photopolymer formulation in a 405 nm LCD printer, comparing cure depth and qualitative adhesion under approximately matched radiant exposures. Three reported irradiances, four exposure times per irradiance and three specimens per condition provide 36 observations. Positive cure-depth data are summarized by a Jacobs working curve and tested for lack of fit against replicate pure error. The pooled fit gives apparent Dp = 67.06 µm and Ec = 16.57 mJ/cm² (R² = 0.986), with statistically detectable lack of fit. Adding irradiance category did not significantly improve the descriptive regression. The findings are restricted to the tested formulation and conditions and do not establish universal reciprocity.
Version 1. English and Spanish PDFs and the CSV containing the 36 measurements are deposited together.
- Demonstrating Without Disclosing: The Verifiability of Technical Performance Under Trade-Secret Protection
View description
This critical essay examines how the technical performance of proprietary, process-dependent photopolymer systems can remain testable without disclosing confidential formulations. Drawing on publicly available documentation for two 3Dresyns material systems, it distinguishes claims about material composition, process-controlled finished-part properties and the conditions required for meaningful adverse testing. The documentary cases are not independent experimental validations. The author is the founder of 3Dresyns and declares his professional interest. Drafting and bilingual review were assisted by AI under human editorial control; these reviews are not external human peer review.
Version 1. English and Spanish editions deposited together.
- From Catalog to Configuration. Multifunctional Photopolymer Systems, Digital Customization, and On-Demand Manufacturing. The 3Dresyns Model
View description
Technical white paper and verification protocol examining configurable multifunctional photopolymer systems, digital customization and on-demand manufacturing through the 3Dresyns model. It distinguishes paid offline development projects from online selection of predefined functional options and examines photochemistry, additives, color, viscosity, printing speed, order architecture, traceability and validation. This is a conceptual and documentary analysis with a proposed empirical verification protocol; it does not report measured production, delivery or customer outcomes. The illustrative 5.79 trillion combinations of choices do not establish the number of physically distinct formulations or commercially available configurations. Version 1. This bilingual record contains the complete English and Spanish editions.
Layout correction, 27 October 2026: table typography has been made consistent in both editions (Table 2 and Annex C). The text, pagination, Version 1 and DOI are unchanged.