Cell Viability Does Not Establish Functional Biocompatibility: Limits of biological testing in 3D-printed photopolymers and a claim-specific evidence concordance framework

Segurola, Juan

2026-11-10 · Report · Version 1

Cell viability is an endpoint-specific observation, not proof of functional biocompatibility or medical-device safety. This critical analysis examines Liao et al. (2025), who studied C2C12 responses and mechanical performance in printed resins; Jönsson et al. (2025), who evaluated wet-autoclave processing, extractables, adipose-derived stem cells and molecular and differentiation endpoints; and Licata et al. (2024), who documented different responses between human induced pluripotent stem cells and fibroblasts. Two studies were selected because they included products of the author's company; Licata was added to examine transfer across cell types. The Liao preprint reports an unfavourable C2C12 response for 3Dresyns Bioflex A10 MB in its tested configurations. That finding must be retained, but it does not alone identify the causal contribution of the supplied formulation, measured optical process, conversion or residual extractables. The Liao protocol included a manufacturer-recommended UNW2 wash followed by heated water and a post-curing intensity reported by the curing-station manufacturer (Phrozen), not measured at the specimens. These details constrain explanations based solely on omitted aqueous washing or assumed low post-cure intensity, without establishing causation. Jönsson observed selected transcriptomic changes despite favourable gross-cell outcomes; differentiation results and their limits are separately considered. We refine a claim-specific evidence concordance (CEC) record distinguishing contextual relevance, reliability, observed direction and experimentally supported evidence transfer. An additional process-control analysis explains the limits of generic supplier instructions and nominal light-source specifications for establishing actual optical exposure, conversion and extractables, and separates the responsibilities of resin supplier, fabricator, testing laboratory and legal device manufacturer. No new biological experiments, clinical inferences, material ranking or validation of CEC are claimed.

Read the book

© Juan Segurola. Rights and exceptions. Specific Zenodo terms prevail.

Version DOI 10.5281/zenodo.24119387 · All versions in Zenodo

3Dresyns by Resyner Technologies S.L.

Related publications

Section overview: Scientific and Technical Publications