Light Intensity versus Energy Dose in Vat Photopolymerization: Experimental Effects on Cure Depth and Adhesion

Segurola, Juan

2026-10-30 · Journal article · Version 1

Abstract from the Zenodo record

Experimental study of a fixed transparent PEEK-like photopolymer formulation in a 405 nm LCD printer, comparing cure depth and qualitative adhesion under approximately matched radiant exposures. Three reported irradiances, four exposure times per irradiance and three specimens per condition provide 36 observations. Positive cure-depth data are summarized by a Jacobs working curve and tested for lack of fit against replicate pure error. The pooled fit gives apparent Dp = 67.06 µm and Ec = 16.57 mJ/cm² (R² = 0.986), with statistically detectable lack of fit. Adding irradiance category did not significantly improve the descriptive regression. The findings are restricted to the tested formulation and conditions and do not establish universal reciprocity.

Version 1. English and Spanish PDFs and the CSV containing the 36 measurements are deposited together.

Full text

© Juan Segurola. Rights and exceptions. Specific Zenodo terms prevail.

Version DOI 10.5281/zenodo.23822733 · All versions in Zenodo

Related publications

Section overview: Scientific and Technical Publications

Explore related technical topics