4D Photopolymer Actuation: Qualification Limits for Biomedical Translation

Segurola, Juan

2026-08-21 · Informe · Versión 1.1

Los títulos y las descripciones bibliográficas se conservan en el idioma del registro original. Los enlaces a los PDF indican los idiomas disponibles.

Two topical sources report soft or thermoresponsive DLP actuators [1,2], while a third studies printing and post-curing of a passive polymeric stent [3]. No retained source demonstrates a vat-printed 4D actuator operating in a biological medium with blocked force or work output and cycle life. This note therefore presents qualification limits, not clinical evidence. RP-02 defines the shared evidence-to-decision and qualification method and is not reproduced here. The corrected public 4Dresyn F-HV1 TDS v1.4 was verified byte-for-byte against the controlled local copy on 21 August 2026.

Texto completo

DOI de esta versión 10.5281/zenodo.22048069 · Todas las versiones en Zenodo

3Dresyns by Resyner Technologies S.L.